Can a simple body scan replace guesswork in dialysis fluid removal?

NCT ID NCT07803029

What the study statuses mean

This study's is highlighted.

Recruitment status, easiest to join first

Recruiting now This study
This trial is taking on new participants right now.
Not yet recruiting
Registered, but not yet taking participants.
By invitation only
Not open to general applications. Only people the study team invites can take part.
Paused
Paused for now. It may or may not start again.
Ongoing
Running, but no longer taking on new participants.
Completed
The trial has finished. Results may not be published yet.
Stopped early
Stopped early, before it reached the end. That can be for many reasons, including safety.
Cancelled
Cancelled before anyone took part.

Expanded access (not trials)

Expanded access
Not a trial. This treatment can be requested outside a study, case by case, for people who qualify.
Expanded access (paused)
Not a trial. The treatment can normally be requested outside a study, but is unavailable right now.
Expanded access (ended)
Not a trial. The treatment could once be requested outside a study, but no longer can.
Approved
The treatment has been approved, so it is available normally rather than through this programme.

When the status isn't known

Details not published
The full record has not been published yet, so there is little to show here.
Status unknown
This status has not been confirmed recently, so it may be out of date.

First seen Sep 03, 2026 · Last updated Sep 04, 2026 · Updated 1 time

Summary

This study tests whether bioimpedance spectroscopy (BIS) devices can accurately measure fluid changes in people undergoing hemodialysis. Researchers will compare raw measurements from three different BIS devices against the actual amount of fluid removed during dialysis and weight changes. They will also measure absolute blood volume. The goal is to see if these devices can help doctors better determine a patient's dry weight and fluid needs.

What this could mean

Our plain-language read of the trial. This is informational only, not medical advice or a prediction.

Active substance
Bioimpedance spectroscopy devices (Fresenius BCM, SFB7, SOZO) compared against ultrafiltration and weight changes
What this could lead to
If the devices prove accurate, doctors could better determine how much fluid to remove during dialysis, improving patient comfort and safety.
What could go wrong
The study is small and observational, and the devices' calculations were designed for healthy people, so they may not work well during dialysis.

This is an AI summary of the original study and may miss details. Read our disclaimer.

Study facts

What this study's own registry entry says, in plain language.

Phase

Not a phased trial

Phase numbers describe drug development. The registry uses this when they do not apply, as it does for trials of devices, procedures or behaviour changes, and for observational studies.

Participants

About 42 people

The number the study aims to enrol. It can still change while the study runs.

Started

May 2025

Expected to finish

Dec 2026

An estimate. End dates often move.

Lead sponsor

Other sponsor

The registry's catch-all category, for sponsors it does not file as a company, a government agency, or a research network.

Who can take part

This study's own entry requirements. Only the study team can say for certain whether you qualify.

Ages

18 years and older

Sex

Anyone

Healthy volunteers

Not accepted

This study is not open to healthy volunteers. The entry requirements below say who it is open to.

Show the full entry requirements

Copied word for word from the study's registry entry, so the wording is the study team's rather than ours.

Inclusion Criteria: Hemodialysis for more than 3 month Hemodynamic stabile during a dialysis session \- Exclusion Criteria: 1. Amputated limbs. 2. Pregnant. 3. Extremity palsy and paralysis. 4. Implanted electronic device (e.g., pacemaker or ICD). 5. Regular use of dialysate sodium proliferation. 6. Hip, knee and shoulder prosthesis. 7. Dialysis fistula in both arms. 8. Inability to give informed consent. 9. History of discontinuation of dialysis treatment prematurely.

Get updates

Get notified about this study

Sign up to get updates when this study changes or when new studies for Hemodialysis are added.

Our safety recommendation!

By submitting, you agree to our Terms of use

Conditions

The condition(s) this trial relates to.

Body Weight

As listed by the trial registrant

The condition terms exactly as the trial's registrant entered them.

How to take part

Only the study team decides who joins. These are the ways to reach them.

  1. The places running it

    1 site. The list below names each one and where it is.

  2. The official record

    ClinicalTrials.gov lists the study team's own contact details, including names and phone numbers. We don't republish those.

    Open the record ↗

  3. A doctor treating you

    A doctor who knows your case can contact a study site on your behalf, and can tell you whether this study is worth pursuing at all.

Contacts and locations

Locations

  • Aarhus University Hospital

    RECRUITING

    Aarhus, Central Denmark, 8200, Denmark

More trials for these conditions

Other studies related to the condition(s) this trial covers.