New shunt device aims to boost heart valve repair results

NCT ID NCT04729933

What the study statuses mean

This study's is highlighted.

Recruitment status, easiest to join first

Recruiting now
This trial is taking on new participants right now.
Not yet recruiting
Registered, but not yet taking participants.
By invitation only
Not open to general applications. Only people the study team invites can take part.
Paused
Paused for now. It may or may not start again.
Ongoing This study
Running, but no longer taking on new participants.
Completed
The trial has finished. Results may not be published yet.
Stopped early
Stopped early, before it reached the end. That can be for many reasons, including safety.
Cancelled
Cancelled before anyone took part.

Expanded access (not trials)

Expanded access
Not a trial. This treatment can be requested outside a study, case by case, for people who qualify.
Expanded access (paused)
Not a trial. The treatment can normally be requested outside a study, but is unavailable right now.
Expanded access (ended)
Not a trial. The treatment could once be requested outside a study, but no longer can.
Approved
The treatment has been approved, so it is available normally rather than through this programme.

When the status isn't known

Details not published
The full record has not been published yet, so there is little to show here.
Status unknown
This status has not been confirmed recently, so it may be out of date.

First seen Jun 27, 2026 · Last updated Aug 06, 2026 · Updated 2 times

Summary

This study tests if adding a tiny shunt (a small passage) between the upper chambers of the heart can lower pressure after a standard valve repair procedure called MitraClip. Ten people with heart failure and a leaky mitral valve will receive the shunt right after their MitraClip. Researchers will watch for safety issues like stroke, heart attack, or device problems over time.

This is an AI summary of the original study and may miss details. Read our disclaimer.

Study facts

What this study's own registry entry says, in plain language.

Phase

Not a phased trial

Phase numbers describe drug development. The registry uses this when they do not apply, as it does for trials of devices, procedures or behaviour changes, and for observational studies.

Participants

16 people

The number who actually took part.

Started

Mar 2021

Expected to finish

Dec 2030

An estimate. End dates often move.

Lead sponsor

Other sponsor

The registry's catch-all category, for sponsors it does not file as a company, a government agency, or a research network.

Who can take part

This study's own entry requirements. Only the study team can say for certain whether you qualify.

Ages

18 years and older

Sex

Anyone

Healthy volunteers

Not accepted

This study is not open to healthy volunteers. The entry requirements below say who it is open to.

Show the full entry requirements

Copied word for word from the study's registry entry, so the wording is the study team's rather than ours.

Inclusion Criteria: 1\. All patients must meet clinical and anatomic eligibility for commercial placement of MitraClip for functional MR, as specified by the MitraClip Instructions for Use (IFU). a. Clinical eligibility for MitraClip: i. Symptomatic secondary MR (moderate-severe \[3+ or 4+\] or greater) due to ischemic or non-ischemic cardiomyopathy ii. NYHA functional class III, or ambulatory IV iii. Maximization of GDMT as directed by the "Heart Team", including an interventional cardiologist (implanting physician), heart failure cardiologist, and cardiothoracic surgeon. This includes adequate treatment for systolic HF (LV dysfunction), rhythm disorders, and coronary disease, if applicable 1. An inhibitor of the reninangiotensin system (RAS inhibitor), including an angiotensin converting enzyme (ACE) inhibitor or angiotensin receptor blocker (ARB) or angiotensin receptor-neprilysin inhibitor (ARNI) and a beta-blocker (BB) 2. Other medications recommended for selected populations, e.g., mineralocorticoid receptor antagonist (MRA) or nitrates/hydralazine should be used in appropriate patients, according to the published guidelines. 3. Patient has been on stable HF medications as determined by the investigator, for at least 1 month, with the exception of diuretic therapy. Stable is defined as no more than a 100% increase or 50% decrease in dose within these periods. 4. Drug intolerance, contraindications, or lack of indications must be attested to by the investigator. 5. Receiving Class I recommended cardiac rhythm management device therapy. 1. If indicated by class I guidelines, cardiac resynchronization therapy (CRT), implanted cardioverter-defibrillator (ICD) or a pacemaker should be implanted at least 3 months prior to device implantation 2. These criteria may be waived if a patient is clinically contraindicated for these therapies or refuses them and must be attested to by the investigator. iv. At least one hospitalization for heart failure in last year OR corrected BNP ≥ 300 pg/mL or corrected NTproBNP ≥ 1500 pg/mL v. Heart team has determined that mitral valve (MV) surgery will not be offered as a treatment option b. Anatomic eligibility for MitraClip: i. LVEF ≥ 20% and ≤ 50% ii. LV end-systolic dimension ≤ 70 mm iii. MV orifice area \> 4.0 cm2 by TEE iv. Minimal calcification in the grasping area v. No leaflet cleft in the grasping area vi. In patients with a degenerative component to MR, the following additional criteria must be met: 1. Flail width \<15 mm 2. Flail gap \<10 mm vii. The primary regurgitant jet is non-commissural, and in the opinion of the implanting investigator can be successfully be treated by the MitraClip (if a secondary jet exists, it must be considered clinically insignificant) viii. Transseptal catheterization and femoral vein access is feasible per investigator 2. Provide written informed consent for study participation and be willing and able to comply with the required tests, treatment instructions and follow-up visits. Exclusion Criteria: Preliminary Exclusion Criteria (PEC) - to assessed by the Preliminary Screen at the baseline visit: 1. Severe pulmonary hypertension, defined as RV systolic pressure or PA systolic pressure \> 70 mmHg, or PVR \> 4 Woods units, measured by any modality (TTE, TEE, cardiac MRI, or pulmonary artery catheterization \[if data available\]). 2. Moderate or severe RV dysfunction defined as TAPSE \<12mm or RVFAC ≤25% as assessed on Baseline TTE, or qualitative assessment of severe RV dysfunction on TTE, TEE, or cardiac MRI. 3. Untreated severe (3+ to 4+) tricuspid or pulmonary regurgitation. 4. Untreated clinically significant coronary disease requiring revascularization 5. Coronary artery bypass grafting, percutaneous coronary intervention, transcatheter aortic valve implantation, or CRT-D implantation within 30 days 6. Aortic or tricuspid valve requiring surgery or transcatheter intervention 7. COPD requiring continuous home oxygen therapy or chronic outpatient steroid use 8. Cerebrovascular accident within prior 30 days 9. Known severe symptomatic carotid stenosis 10. Carotid surgery or stenting within prior 30 days 11. ACC/AHA Stage D heart failure 12. Presence of any of the following: 1. Hypertrophy cardiomyopathy, restrictive cardiomyopathy, constrictive pericarditis, or any other structural heart disease causing heart failure other than dilated cardiomyopathy of either ischemic or non-ischemic etiology 2. Infiltrative cardiomyopathy (e.g. amyloidosis, hemochromatosis, sarcoidosis) 13. Leaflet anatomy which may preclude MitraClip implantation 14. Hemodynamic instability defined as systolic pressure \< 90 mmHg with or without afterload reduction, cardiogenic shock or the need for inotropic support or intra-aortic balloon pump or other hemodynamic support device. 15. Need for surgery within 12 months 16. Life expectancy \< 1 year due to non-cardiac conditions 17. Status 1 for cardiac transplant or history of cardiac transplant 18. Modified Rankin score ≥ 4 for disability 19. Prior mitral valve leaflet surgery or any currently implanted prosthetic mitral valve, or any prior transcatheter mitral valve procedure 20. Echocardiographic evidence of intracardiac mass, thrombus, or vegetation 21. Active endocarditis or active rheumatic heart disease or leaflets degenerated from rheumatic disease (i.e., noncompliant, perforated) 22. Active infection requiring antibiotic therapy 23. TEE is contraindicated or high risk 24. Pregnant or planning pregnancy within 12 months 25. Known hypersensitivity or contraindication to procedural medications that cannot be adequately treated 26. Known allergy to nickel. 27. Patient is otherwise not appropriate for the study as determined by the investigator or the Eligibility Committee, for which the reasons must be documented. 28. Patient belongs to a vulnerable population per investigator's judgment or patient has any kind of disorder that compromises his/her ability to give written informed consent and/or to comply with study procedures. Final Exclusion Criteria (FEC) - Assessed by the Final Screening, performed at time of cardiac catheterization prior to device placement (Study Intervention Visit) 29. Presence of severe pulmonary hypertension assessed by invasive hemodynamic measurement with pulmonary artery catheterization prior to MitraClip placement, defined as PA systolic pressure \> 70 mmHg or PVR \> 4 Woods units. 30. Anatomical anomaly on TEE that precludes implantation of the study device across the interatrial communication created by the MitraClip procedure, including: 1. A posterior rim between the septum secundum and aorta (i.e. aortic rim) of \< 5 mm. 2. Atrial septal aneurysm defined as ≥ 10 mm of phasic septal excursion into either atrium or a sum total excursion of ≥ 15 mm during the cardiorespiratory cycle, with a base of ≥ 15 mm. 31. Moderate or worse MR ≥2+ at the end of MitraClip treatment (i.e. MR must be \<2+ by TTE, TEE, invasive hemodynamics, or left ventriculography) 32. Key hemodynamic exclusions after MitraClip treatment: 1. Mean LAP ≤ 20 mmHg following final result from MitraClip placement (i.e. mean LAP must be elevated \> 20 mmHg after completion of MitraClip). 2. Difference between mean LAP and mean RAP \< 5mmHg after MitraClip placement (i.e. difference between LAP - RAP must be ≥ 5 mmHg). 3. If the patient meets these hemodynamic exclusion criteria and mean arterial pressure (MAP) is \< 90 mmHg, the MAP may be increased to ≥ 90 mmHg and repeat pressure measurements obtained in order to evaluate eligibility. i. IV fluids and medications may be given to support MAP to a goal ≥ 90 mmHg if necessary. 33. Characteristics of septal defect 1. Angle of placement of V-WAVE shunt should be no more than 135 degrees to prevent slippage through the septum, and 2. Septal defect created by MtrraClip delivery system must be 8mm or smaller, in any dimention, without evidence of a tear in the septum 34. Patient is otherwise not appropriate for study as determined by the Investigator.

Get updates

Get notified about this study

Sign up to get updates when this study changes or when new studies for Heart failure are added.

Vår säkerhetsrekommendation!

Genom att skicka in godkänner du våra Användarvillkor

Conditions

The condition(s) this trial relates to.

As listed by the trial registrant

The condition terms exactly as the trial's registrant entered them.

Contacts and locations

Locations

  • Cleveland Clinic

    Cleveland, Ohio, 44195, United States

More trials for these conditions

Other studies related to the condition(s) this trial covers.