New stent shows promise in unclogging heart arteries
NCT ID NCT03466151
First seen Jun 27, 2026 · Last updated Jun 27, 2026
Summary
This study tests a newer drug-coated stent (Resolute Onyx) against an older one (Resolute Integrity) in 550 people with blocked heart arteries in China. The goal is to see if the new stent works better at keeping arteries open after angioplasty. Participants receive one of the two stents during a standard procedure to restore blood flow.
This is an AI summary of the original study and may miss details. Read our disclaimer.
Study facts
What this study's own registry entry says, in plain language.
- Phase
-
Not a phased trial
Phase numbers describe drug development. The registry uses this when they do not apply, as it does for trials of devices, procedures or behaviour changes, and for observational studies.
- Participants
-
550 people
The number who actually took part.
- Started
-
Apr 2018
- Expected to finish
-
Jul 2026
An estimate. End dates often move.
- Lead sponsor
-
A company
The lead sponsor is a pharmaceutical, biotech, or medical-device company.
Who can take part
This study's own entry requirements. Only the study team can say for certain whether you qualify.
- Ages
-
18 years and older
- Sex
-
Anyone
- Healthy volunteers
-
Not accepted
This study is not open to healthy volunteers. The entry requirements below say who it is open to.
Show the full entry requirements Hide the full entry requirements
Copied word for word from the study's registry entry, so the wording is the study team's rather than ours.
Key Inclusion Criteria: * The subject is an acceptable candidate for treatment with a drug-eluting stent in accordance with the applicable guidelines on percutaneous coronary interventions, the IB of Resolute Onyx stent, and the IFU of Resolute Integrity stent * The subject requires treatment of up to 3 target lesions in up to 2 separate target vessels \[2 target lesions in 1 vessel (including its side branches) and 1 target lesion in a separate vessel(including its side branches)\] amenable to treatment with stents with diameter from 2.25 mm to 4.0 mm Key Exclusion Criteria: * Known hypersensitivity or contraindication to aspirin, heparin, bivalirudin, P2Y12 inhibitors, mTOR inhibiting drugs such as zotarolimus, Biolimus A9 (or its derivatives), cobalt, nickel, platinum, iridium, chromium, molybdenum, polymer coatings (e.g. BioLinx) or a sensitivity to contrast media, which cannot be adequately pre-medicated * PCI of the target vessel within 9 months prior to the procedure * Active bleeding * Subjects with a life expectancy of less than 12 months * Participation in another clinical study * Pregnant, or lactating women
Get updates
Get notified about this study
Sign up to get updates when this study changes or when new studies for Arteriosclerosis are added.
Genom att skicka in godkänner du våra Användarvillkor
Conditions
The condition(s) this trial relates to.
As listed by the trial registrant
The condition terms exactly as the trial's registrant entered them.
Contacts and locations
Locations
-
Fuwai Hospital, Chinese Academy of Medical Science
Beijing, 100037, China
-
Shengjing Hospital of China Medical University
Shenyang, Liaoning, China
More trials for these conditions
Other studies related to the condition(s) this trial covers.
- Can a nurse and a neighbor help tame chronic disease?
- Two eggs a day put to the test for heart health
- Heart bypass surgeons test which vein layout keeps grafts open
- A soft patch that watches your heart beat in real time
- Zapping the ear: a new way to stop Post-Surgery heart rhythm problems?
- Squeeze a ball, lower your blood pressure? heart trial puts handgrip exercise to the test