Den här översättningen är inte klar ännu. Den här sidan är just nu på engelska.

Gå till den engelska sidan

New CT software aims to sharpen images of shoulders, hips, and knees

NCT ID NCT07317453

What the study statuses mean

This study's is highlighted.

Recruitment status, easiest to join first

Recruiting now
This trial is taking on new participants right now.
Not yet recruiting This study
Registered, but not yet taking participants.
By invitation only
Not open to general applications. Only people the study team invites can take part.
Paused
Paused for now. It may or may not start again.
Ongoing
Running, but no longer taking on new participants.
Completed
The trial has finished. Results may not be published yet.
Stopped early
Stopped early, before it reached the end. That can be for many reasons, including safety.
Cancelled
Cancelled before anyone took part.

Expanded access (not trials)

Expanded access
Not a trial. This treatment can be requested outside a study, case by case, for people who qualify.
Expanded access (paused)
Not a trial. The treatment can normally be requested outside a study, but is unavailable right now.
Expanded access (ended)
Not a trial. The treatment could once be requested outside a study, but no longer can.
Approved
The treatment has been approved, so it is available normally rather than through this programme.

When the status isn't known

Details not published
The full record has not been published yet, so there is little to show here.
Status unknown
This status has not been confirmed recently, so it may be out of date.

First seen Jun 27, 2026 · Last updated Aug 26, 2026 · Updated 2 times

Summary

This study tests a new image reconstruction software called Precise Image for CT scans of the shoulder, hip, and knee in adults. Researchers want to see if it produces images as good as or better than the current standard software. About 84 adults will have their existing CT scans analyzed. The goal is to improve image quality and doctor confidence when diagnosing joint problems.

What this could mean

Our plain-language read of the trial. This is informational only, not medical advice or a prediction.

Active substance
Precise Image reconstruction algorithm (software)
What this could lead to
If successful, this could improve CT image quality for joint scans, potentially leading to clearer images and better diagnostic confidence for doctors.
What could go wrong
This is an early-stage, non-randomized study with only 84 participants. The new algorithm may not prove superior or could have unexpected limitations in real-world use.

This is an AI summary of the original study and may miss details. Read our disclaimer.

Study facts

What this study's own registry entry says, in plain language.

Participants

About 84 people

The number the study aims to enrol. It can still change while the study runs.

Expected to start

Jan 2027

An estimate. Start dates often move.

Expected to finish

Dec 2027

An estimate. End dates often move.

Lead sponsor

A company

The lead sponsor is a pharmaceutical, biotech, or medical-device company.

Who can take part

This study's own entry requirements. Only the study team can say for certain whether you qualify.

Who is studied

Adults

Ages

19 years and older

Sex

Anyone

Healthy volunteers

Not accepted

This study is not open to healthy volunteers. The entry requirements below say who it is open to.

Show the full entry requirements

Copied word for word from the study's registry entry, so the wording is the study team's rather than ours.

Inclusion Criteria: * Subjects scanned by FDA-cleared and marketed Philips Incisive CT or CT 5300 systems, and according to the department standard of care clinical protocols for the applicable anatomies. * Subject age: Above 18 years old. Exclusion Criteria: * Subject age: 18 years old and below. * Scans that were acquired using generic 'Body' scan type (as Precise Image does not support generic 'Body' scan types). * Scans that were acquired using a kilovoltage peak of 70 kVp (as Precise Image does not support a kilovoltage peak lower than 80 kVp). * Scans that the site radiologists have deemed as non-diagnostic image quality in standard practice (e.g. patient movement). * Scans that failed internal technical checks (e.g., corrupt files, failure to reconstruct).

Get updates

Get notified about this study

Sign up to get updates when this study changes or when new studies for Computed tomography are added.

Vår säkerhetsrekommendation!

Genom att skicka in godkänner du våra Användarvillkor

As listed by the trial registrant

The condition terms exactly as the trial's registrant entered them.

How to take part

Only the study team decides who joins. These are the ways to reach them.

  1. The official record

    The full official record for this study. This one lists no contact details, but it is the first place any would appear.

    Open the record ↗

  2. A doctor treating you

    A doctor who knows your case can contact a study site on your behalf, and can tell you whether this study is worth pursuing at all.

More trials for these conditions

Other studies related to the condition(s) this trial covers.