New study targets tough heart valve cases with advanced device
NCT ID NCT07450196
First seen Jun 27, 2026 · Last updated Jun 27, 2026
Summary
This study looks at how safe and effective the SAPIEN 3 heart valve is for people with a certain type of bicuspid aortic valve stenosis (Type-0). About 170 people in China will be observed after the procedure to track serious problems like death, stroke, or rehospitalization. The goal is to see if this valve works well for this challenging anatomy.
This is an AI summary of the original study and may miss details. Read our disclaimer.
Study facts
What this study's own registry entry says, in plain language.
- Participants
-
About 170 people
The number the study aims to enrol. It can still change while the study runs.
- Expected to start
-
Apr 2026
An estimate. Start dates often move.
- Expected to finish
-
Aug 2029
An estimate. End dates often move.
- Lead sponsor
-
Other sponsor
The registry's catch-all category, for sponsors it does not file as a company, a government agency, or a research network.
Who can take part
This study's own entry requirements. Only the study team can say for certain whether you qualify.
Who is studied
severe symptomatic aortic valve stenosis (AS) patients with type-0 bicuspid anatomy
- Ages
-
50 years and older
- Sex
-
Anyone
- Healthy volunteers
-
Not accepted
This study is not open to healthy volunteers. The entry requirements below say who it is open to.
Show the full entry requirements Hide the full entry requirements
Copied word for word from the study's registry entry, so the wording is the study team's rather than ours.
Inclusion Criteria: * Age ≥50 years, and after thorough physician-patient discussion and shared decision-making, willing to undergo or accept TAVR. * Severe AS, defined as follows: a) For symptomatic patients: i) Aortic valve area ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), OR mean gradient ≥40 mm Hg, OR Maximal aortic valve velocity ≥4.0 m/sec by transthoracic echocardiography at rest b) For asymptomatic patients: i) Very severe AS with an aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND maximal aortic velocity ≥5.0 m/sec, or mean gradient ≥60 mm Hg by transthoracic echocardiography at rest, OR ii) Aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND a mean gradient ≥40 mm Hg or maximal aortic valve velocity ≥4.0 m/sec by transthoracic echocardiography at rest, AND an exercise tolerance test that demonstrates a limited exercise capacity, abnormal BP response, or arrhythmia OR iii) Aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND mean gradient ≥40 mmHg, or maximal aortic valve velocity ≥4.0 m/sec by transthoracic echocardiography at rest, AND a left ventricular ejection fraction \<50%. * Type-0 bicuspid aortic valve anatomy confirmed by multi-detector computed tomography (MDCT). * The subject and the treating physician agree that the subject will return for all required post-procedure follow-up visits. * Adequate iliofemoral access and acceptable level of vessel calcification and tortuosity for safe device implant. * The study patient has provided written informed consent. Exclusion Criteria: * Challenging calcification based on physician's experience and discretion * Aortic valve is a congenital unicuspid valve, congenital Type-1 or Type-2 bicuspid valve, tricuspid or quadricuspid valve * Severe femoral, iliac or aortic atherosclerosis, calcification, coarctation, aneurysm or tortuosity, which prevents transfemoral TAVR * Need for open heart surgery (including severe aortic regurgitation, mitral regurgitation or stenosis, or tricuspid regurgitation, congenital heart disease, AF, complex coronary artery disease) * Pre-existing mechanical or bioprosthetic valve in any position * Hemodynamic or respiratory instability requiring inotropic support, mechanical ventilation or mechanical heart assistance within 30 days of the screening visit * Emergency interventional/surgical procedures within 30 days of the valve implant procedure * Hypertrophic cardiomyopathy with obstruction * Ventricular dysfunction with LVEF \< 30% * Cardiac imaging (echo, CT, and/or MRI) evidence of ventricular mass, thrombus or vegetation * Renal replacement therapy at the time of screening * Estimated life expectancy \< 12 months * Currently participating in an investigational drug or another device study. Note: Trials requiring extended follow-up for products that were investigational, but have since become commercially available, are not considered investigational trials. Observational studies are not considered exclusionary.
Get updates
Get notified about this study
Sign up to get updates when this study changes or when new studies for Aortic stenosis are added.
Genom att skicka in godkänner du våra Användarvillkor
Conditions
The condition(s) this trial relates to.
As listed by the trial registrant
The condition terms exactly as the trial's registrant entered them.
How to take part
Only the study team decides who joins. These are the ways to reach them.
-
The places running it
1 site. The list below names each one and where it is.
-
The official record
ClinicalTrials.gov lists the study team's own contact details, including names and phone numbers. We don't republish those.
-
A doctor treating you
A doctor who knows your case can contact a study site on your behalf, and can tell you whether this study is worth pursuing at all.
Contacts and locations
Locations
-
Chinese Academy of Medical Sciences, Fuwai Hospital, Beijing
Beijing, Beijing Municipality, 100037, China
More trials for these conditions
Other studies related to the condition(s) this trial covers.
- AI turns routine heart tracings into an early warning for a silent valve disease
- PET scans may reveal which aortic valves will worsen
- Can a new heart valve offer a safer fix for aortic stenosis?
- Can Open-Heart surgery outperform a Tube-Based valve fix?
- Can a new heart valve restore quality of life?
- Does replacing a heart valve clear fluid from the lungs?