Den här översättningen är inte klar ännu. Den här sidan är just nu på engelska.

Gå till den engelska sidan

New stent aims to fix aortic arch without open surgery

NCT ID NCT07564375

What the study statuses mean

This study's is highlighted.

Recruitment status, easiest to join first

Recruiting now This study
This trial is taking on new participants right now.
Not yet recruiting
Registered, but not yet taking participants.
By invitation only
Not open to general applications. Only people the study team invites can take part.
Paused
Paused for now. It may or may not start again.
Ongoing
Running, but no longer taking on new participants.
Completed
The trial has finished. Results may not be published yet.
Stopped early
Stopped early, before it reached the end. That can be for many reasons, including safety.
Cancelled
Cancelled before anyone took part.

Expanded access (not trials)

Expanded access
Not a trial. This treatment can be requested outside a study, case by case, for people who qualify.
Expanded access (paused)
Not a trial. The treatment can normally be requested outside a study, but is unavailable right now.
Expanded access (ended)
Not a trial. The treatment could once be requested outside a study, but no longer can.
Approved
The treatment has been approved, so it is available normally rather than through this programme.

When the status isn't known

Details not published
The full record has not been published yet, so there is little to show here.
Status unknown
This status has not been confirmed recently, so it may be out of date.

First seen Jun 27, 2026 · Last updated Sep 17, 2026 · Updated 2 times

Summary

This early study tests a new device called the GORE Multibranch Arch Endoprosthesis for people with aortic arch conditions like aneurysms or dissections. The device is placed inside the blood vessel to repair the damaged area. The study will enroll 20 participants and follow them for 5 years to check if the device is safe and works as intended.

What this could mean

Our plain-language read of the trial. This is informational only, not medical advice or a prediction.

Active substance
GORE Multibranch Arch Endoprosthesis (MBA device) and GORE Ascending Stent Graft (ASG device)
What this could lead to
If successful, this device could offer a less invasive way to treat complex aortic arch problems, potentially avoiding open-heart surgery.
What could go wrong
This is a very early, small study (20 people) focused only on safety. The device may fail or cause serious complications like stroke or kidney failure.

This is an AI summary of the original study and may miss details. Read our disclaimer.

Study facts

What this study's own registry entry says, in plain language.

Phase

Not a phased trial

Phase numbers describe drug development. The registry uses this when they do not apply, as it does for trials of devices, procedures or behaviour changes, and for observational studies.

Participants

About 20 people

The number the study aims to enrol. It can still change while the study runs.

Started

Sep 2026

Expected to finish

Aug 2033

An estimate. End dates often move.

Lead sponsor

A company

The lead sponsor is a pharmaceutical, biotech, or medical-device company.

Who can take part

This study's own entry requirements. Only the study team can say for certain whether you qualify.

Ages

18 years and older

Sex

Anyone

Healthy volunteers

Not accepted

This study is not open to healthy volunteers. The entry requirements below say who it is open to.

Show the full entry requirements

Copied word for word from the study's registry entry, so the wording is the study team's rather than ours.

Inclusion Criteria: The subject is / has: 1. Thoracic pathologies with involvement of the arch branch vessels, that are compatible with the treatment requirements of the MBA device, and meeting any of the following criteria: a) Aneurysm and Isolated Lesions: i. Fusiform aneurysm (≥ 55 mm or documented growth rate \> 0.5 cm/year). ii. Saccular aneurysm (no diameter criteria). iii. Pseudoaneurysms (\> 30 days post-surgery, no diameter criteria). iv. Penetrating Aortic Ulcers (PAUs) without intramural hematoma (IMH) (no diameter criteria). b) Aortic dissection: i. Uncomplicated and high-risk chronic de novo (\> 90 days) Type B aortic dissection with primary entry tear in the arch or descending thoracic aorta. ii. Residual aortic dissection following surgical repair of Type A aortic dissection requiring treatment (\> 30 days post-treatment). iii. Proximal extension of prior endovascular repair (\> 30 days post-treatment and \> 90 days post-dissection) of a Type B dissection requiring treatment. iv. Pseudoaneurysms, following open surgical repair of a Type A dissection (\> 30 days post-surgery, no diameter criteria). 2. Anatomic compatibility with MBA device and other devices required for proximal or distal extensions based on Gore's review. 1. Adequate vascular access via transfemoral or retroperitoneal approach. 2. Appropriate vascular access to allow for through-wire access to the brachiocephalic artery, LCCA, and LSA. 3. Proximal Aortic Landing Zone: i. Landing zone is native aorta, surgical graft, or previously implanted GORE thoracic stent graft. ii. Landing zone diameter between 27 mm - 48 mm. iii. Acceptable ascending aorta outer curvature length for the required MBA device. 1. Proximal segment length (length from distal edge of brachiocephalic artery to distal edge of the most distal coronary artery) must be ≥ 2 cm longer than the "AC Proximal End to BCA Portal Length" for the selected Aortic Component or ≥ 3 cm if the landing zone is \> 42 mm. 2. For patients with patent bypass graft from the ascending aorta, proximal extent of landing zone must be ≥ 1 cm distal to the bypass graft. iv. Lesion location is ≥ 2 cm distal to the most distal coronary artery ostium. v. For patients with an existing transcatheter aortic valve replacement (TAVR) there must be a sufficient proximal landing zone to avoid interference with the required MBA device (including any proximal extensions with the ASG device). vi. Proximal landing zone must be ≥ 2 cm in the ascending aorta. 1. For patients with prior replacement of the ascending aorta and / or aortic arch by surgical graft, there must be ≥ 2 cm overlap of MBA device and previously implanted graft. 2. For patients with a de novo aortic dissection, the primary entry tear must be located ≥ 2 cm distal to the proximal extent of the MBA device (including any proximal extensions) and the proximal edge of the stent graft must land in non-dissected aorta. vii. Landing zone cannot be aneurysmal, heavily calcified, or heavily thrombosed. d) Branch Vessel Landing Zone: i. Length of ≥ 2.5 cm proximal to first major branch vessel. ii. Target branch vessel inner diameter of 11-18 mm for the 12 mm portal, and 6-15 mm for the 8 mm portal. iii. Target branch vessel landing zone must be in native aorta that cannot be heavily calcified, or heavily thrombosed. iv. All three arch target vessels must have appropriate anatomy for cannulation (including through-wire access) and treatment with MBA branch components. e) Distal Aortic Landing Zone (aneurysms and isolated lesions only): i. Outer curvature length must be ≥ 2 cm proximal to the celiac artery. ii. Aortic inner diameters between 16-42 mm. iii. Landing zone cannot be aneurysmal, heavily calcified, or heavily thrombosed. iv. Landing zone in native aorta, surgical graft, or previously implanted GORE thoracic stent graft. 3. Age ≥ 18 years at time of informed consent signature. 4. Informed Consent Form (ICF) signed by the subject or legally authorized representative (LAR), according to local regulation. 5. Agrees to comply with protocol requirements, including imaging and five year (60 month) follow-up. 6. Considered high-risk for open surgical repair by meeting one or more of the following criteria: 1. ≥ 75 years of age 2. Previous median sternotomy 3. Documented identification of other subject-specific risk factors (e.g., medical history, active medical diagnosis) by a study investigator and an experienced open ascending and / or aortic arch surgeon (e.g., cardiothoracic surgeon). 7. Considered high-risk for surgical debranching by meeting one or more of the following criteria: 1. Prior neck surgery or radiation 2. Neck anatomy / body habitus impeding carotid access or safe bypass tunneling 3. Dysphagia 4. Elevated risk for post-operative infection (e.g., malnutrition, uncontrolled diabetes (hemoglobin A1c \> 9%), current treatment with immunosuppressant therapy or chemotherapy) 5. Reduced pulmonary function (e.g., severe chronic obstructive pulmonary disease (COPD), current or anticipated tracheostomy) 6. Clinical Frailty Scale score 6-7 7. Documented identification of other subject-specific risk factors which would pose high risk for surgical debranching (e.g., medical history, active medical diagnosis) by a study investigator Exclusion Criteria: The subject is / has: 1. De novo Type A dissection 2. Requires immediate treatment. 3. Arch vessels with dissection extending into the intended landing zones. 4. Anticipated need for coronary or aortic valve intervention within one year post-treatment. 5. Any aortic valve repair or replacement including transcatheter aortic valve replacement (TAVR) or coronary artery intervention within 30 days prior to treatment. 6. Complex percutaneous coronary intervention (PCI) within 30 days prior to treatment. 7. Open chest surgical repair within 30 days prior to treatment. 8. Any open or interventional repair of either carotid artery within 30 days prior to treatment. 9. Presence of Intramural Hematoma (IMH) in landing zones. 10. Prosthetic heart valve in the aortic position that precludes safe delivery of any study device. 11. Aortic insufficiency (AI) grade 3 or greater. 12. Previous endovascular repair with a non-Gore device that would interfere with or result in contact with planned repair. 13. Concomitant vascular disease, including disease associated with the great and upper extremity vessels, requiring treatment that is not planned for index endovascular procedure. 14. Any stroke or MI within 90 days prior to treatment. 15. Presence of protruding and / or irregular thrombus and / or atheroma in the ascending aorta or aortic arch or any other factor that could increase the risk of stroke based on Gore's review. 16. Any chronic condition that is not well controlled and that is known to increase stroke risk. 17. Known degenerative connective tissue disease (e.g., Marfan's or Ehler-Danlos Syndrome (EDS)). 18. Participation in investigational drug or medical device study within one year of enrollment unless approved by the sponsor. 19. Known medical, social, or psychological issues that the Investigator believes may interfere with treatment or follow-up, such as a history of drug abuse within one year of treatment. 20. Pregnant at time of procedure or planning to become pregnant within the first 12-months of participation in the study. 21. Active infected aorta, mycotic aneurysm. 22. Active systemic infection (e.g., infection requiring treatment with parenteral anti-infective medication). 23. Renal failure, defined as patients with an estimated Glomerular Filtration Rate (eGFR) \< 30 (mL/min/1.73 m2) or currently requiring dialysis. 24. Life expectancy \<12 months. 25. Known sensitivities or allergies to the device materials. 26. Known hypersensitivity or contraindication to anticoagulants or contrast media, which is not amenable to pre-treatment. 27. Body habitus or other medical condition which prevents adequate fluoroscopic and CT visualization of the aorta. 28. Previous instance of Heparin Induced Thrombocytopenia type 2 (HIT-2) or known hypersensitivity to heparin or a history of a hypercoagulability disorder and / or state. 29. Severe Congestive Heart Failure (CHF) (New York Heart Association (NYHA) functional class IV). 30. Acute Coronary Syndrome (ACS) including unstable angina.

Get updates

Get notified about this study

Sign up to get updates when this study changes or when new studies for Penetrating aortic ulcers (PAUS) are added.

Vår säkerhetsrekommendation!

Genom att skicka in godkänner du våra Användarvillkor

Conditions

The condition(s) this trial relates to.

Aneurysm, False Dissection, Thoracic Aorta Penetrating Atherosclerotic Ulcer thoracic aortic aneurysm

As listed by the trial registrant

The condition terms exactly as the trial's registrant entered them.

How to take part

Only the study team decides who joins. These are the ways to reach them.

  1. The places running it

    2 sites. The list below names each one and where it is.

  2. The official record

    ClinicalTrials.gov lists the study team's own contact details, including names and phone numbers. We don't republish those.

    Open the record ↗

  3. A doctor treating you

    A doctor who knows your case can contact a study site on your behalf, and can tell you whether this study is worth pursuing at all.

Contacts and locations

Locations

  • Baylor Research Institute

    RECRUITING

    Plano, Texas, 75093, United States

  • University of Southern California

    RECRUITING

    Los Angeles, California, 90033, United States

More trials for these conditions

Other studies related to the condition(s) this trial covers.